Demonstration and measurement of gas engine CHP plant with RECCAT reactor for removal of inflammary emissions
The project demonstrated and documented the RECCAT system in full scale on the 1.5 MW Rolls Royce engine of Rask Mølle heating plant. Too small reactor size entailed reduced ability to maintain the required temperature in the catalyst material and thus significant activity drops during the project. Correct dimensioning allows the RECCAT system to r
Results
The project demonstrated and documented the RECCAT system in full scale on the 1.5 MW Rolls Royce engine of Rask Mølle heating plant. Too small reactor size entailed reduced ability to maintain the required temperature in the catalyst material and thus significant activity drops during the project. Correct dimensioning allows the RECCAT system to remove more than 90% of UHC in the flue gas, more than 95% of formaldehyde and more than 98% of CO. The technology is not competitive considering the current prices of steel and other materials, thus providing no basis for further installations.
Key figures
Period:
2005 - 2009
Funding year:
2005
Own financial contribution:
0.00 mio. DKK
Grant:
1.14 mio. DKK
Funding rate:
100 %
Project budget:
1.14 mio. DKK
Category
Oprindelig title
Demonstration og målinger på gasmotorbaseret kraftvarmeanlæg med RECCAT-reaktor til fjernelse af brændbare emissioner
Programme
ForskEL
Technology
Other
Project type
Demonstration
Case no.
5782
Participants
RECCAT ApS (Main Responsible)
Partners and economy
Partner | Subsidy | Auto financing |
---|---|---|
No entries available. |
Contact
Kontakperson
Rasmussen, Niels Bjarne
Comtact information
RECCAT ApSDr. Neergaards Vej 5 B
DK-2970 Hørsholm, Danmark
Rasmussen, Niels Bjarne , 21471752, info@reccat.dk
Øvr. Partnere:
Contact email
info@reccat.dk