Calculation of energy efficiency for cooling system and heat pumps in Be10

The project will contribute with a more correct calculation of the actual energy consumption for heat pumps and cooling systems in the simulation programme Be10 by designing and implement better methods for calculation of efficiency and energy consumption for cooling system and heat pumps, for easier decision making of the most energy efficient performance.

The project has developed a new method for the calculation of heat pumps in Be10. The method is based on the new standards for measuring heat pumps which introduces SCOP values for heat pumps.
Project description

The project will contribute with a more correct calculation of the actual energy consumption for heat pumps and cooling systems in the simulation programme Be10 by designing and implement better methods for calculation of efficiency and energy consumption for cooling system and heat pumps, for easier decision making of the most energy efficient performance.

Results
The project has developed a new method for the calculation of heat pumps in Be10. The method is based on the new standards for measuring heat pumps which introduces SCOP values ​​for heat pumps. The method calculates heat pumps' efficiency and heat output for each hour in each month of the year. The results thereby takes better account of the variations that occur in the load of heat pumps, providing a significantly more nuanced picture of the performance, especially during cold periods. The project focuses on the treatment of air-air, air-water and water-water heat pumps (geothermal heat pumps). The other heat pumps will be treated according to the same principles as equivalent to the old calculation principles.

The calculation program Be10 has a model for calculation of heat pumps. In the current calculation method for heat pumps in Be10 is in a simple manner catered for heat pumps operating at partial load, which does not reflect heat pumps varying operating at the full range of outdoor temperatures over the year. The reason is that the calculation of Be10 today rely on one average temperature per. month.

Be10 calculation does not reflect adequately the low temperatures during winter where heat can be large and the efficiency of the heat pump is small, and where the use of backup heat will be needed to deliver the required amount of heat for home heating or hot water. The calculation also does not reflect the outside temperature at which the required heat is small, and the efficiency of the heat pump can be very different. The current Be10 heat pump calculation may therefore be subject to uncertainty in relation to a more detailed calculation.

Key figures

Period:
2012 - 2015
Funding year:
2012
Own financial contribution:
0.52 mio. DKK
Grant:
0.56 mio. DKK
Funding rate:
52 %
Project budget:
1.07 mio. DKK

Category

Oprindelig title
Beregning af energieffektivitet for køleanlæg og varmepumper i Be10
Programme
ELFORSK
Technology
Energy efficiency
Case no.
ELFORSK 344-045

Participants

Teknologisk Institut (Main Responsible)
Partners and economy
Partner Subsidy Auto financing
Aalborg Universitet (Fredrik Bajers Vej)
VARMEPUMPEFABRIKANTFORENINGEN